Vishal Engineers & Galvanizers works according to the standards of IS 4759 for structured steel and IS 12594 for reinforcement and accommodateble to the international standards also. There are quality control measures taken at all the crucial stages of the process.
Inspections stages for Hot Dip Galvanizing process are:
• Inspection of black material
• Inspection after degreasing
• Acid Pickling
• Fluxing
• After Galvanizing
Visual
Mass of Zinc in Laboratory
Coating thickness measurement
The work on each stages is well tested and in accordance to the Indian Standards.
Laboratory facilities
Vishal Engineers & Galvanizers also has the testing facilities. The laboratory testing facilities are given below:
• Acid concentration test at regular interval
• Flux concentration test at regular interval
• Rinsing water Ph value testing
• Mass of zinc
Zinc Coating thickness measurement with Magnetic Gauge and ED current method.
Instruments
• Dial type, Make: Physix, Germany
• Digital type, Make: Physix, Germany
• Hammer test
• Knife test